Middleby Marshall PS200 series User Manual

Page 91

Advertising
background image

90

Figure 58

PS570S gas train

Figure 59

PS570G or PS555 gas train

Manual shutoff

valve, 1/2”

23115-0009

1/2” union

23051-0003

Combination gas

control valve, 1/2”

45688

Solenoid valve, 1/2”

28091-0017

Pilot

pressure

tap

30185

Bypass line

(1/4” aluminum tubing)

15125-0002

(per foot)

Pilot line

(1/4” aluminum tubing)

15125-0002

(per foot)

Burner blower and

motor assy, 120V

with centrifugal

safety switch

27170-0011

Air shutter

42810-0087

NOT SHOWN

(components are

installed on back wall

of machinery

compartment):

240Vp:120Vs blower

motor transformer

27170-0017

Relay

27170-0016

OVENS RETROFITTED

WITH MODULATING

GAS SYSTEM ONLY:

M420 modulating

valve, 1/2”

41647

Manual shutoff

valve, 1/2”

23115-0009

1/2” union

23051-0003

Combination gas

control valve, 1/2”

45688

Pilot pressure tap

30185

Pilot line

(1/4” aluminum tubing)

15125-0002

(per foot)

M420 modulating

valve, 1/2”

41647

Air shutter

42810-0087

Burner blower

and motor assy,

208/240V

27170-0287

Air tube

(silicone rubber)

22450-0297

(per foot)

TO POSITIVE (+)

SIDE OF AIR

SWITCH

Flexible air hose

22450-0255

Flexible air hose

22450-0255

SECTION 3 - SERVICING COMPONENTS

Advertising
This manual is related to the following products: