Oven thermocouple kit – Middleby Marshall PS200 series User Manual

Page 57

Advertising
background image

56

1

Instructions for Service Kits P/Ns 33984 and 33985

Oven Thermocouple Kit

Middleby Cooking Systems Group • 1400 Toastmaster Drive • Elgin, IL 60120 • USA • (847) 741-3300 • FAX (847) 741-4406

This Service Kit provides the parts and instructions necessary to replace one temperature-sensing or high limit thermo-

couple in any of the following Middleby Marshall oven models:

P/N 34701 • Rev. C • V1 • 11/01

KIT CONTENTS - KIT P/N 33984

P/N

Qty. Description

33812-1

1

Thermocouple, type J, 6” L

B301A8861

2

Screw, hex wshr hd #6 x 3/8”

21292-0001

3

Screw, hex wshr hd #10-16 x 3/4”

27276-0001

1

Cable clamp, nylon

41687

1

Attachment plate, PS360 rear thermocouple

34701

1

Instructions

These instructions include replacement procedures for ovens built with the current flanged thermocouple, AND for ovens

built with the obsolete thermocouple without a flange (P/N 28071-0001).

• PS200 Series uses Kit P/N 33985

• PS360 Series uses Kit P/N 33984

• PS536 uses Kit P/N 33985

• PS555 uses Kit P/N 33984

• PS570 uses Kit P/N 33984

IMPORTANT - READ THIS BEFORE YOU BEGIN!
The thermocouple in your Kit has three leads:
•

The red and white leads connect directly to the thermocouple terminals on the oven’s temperature controller (or high

limit control module, as appropriate), or to a local terminal block that in turn is connected to one of these units.

•

The uninsulated lead is a ground wire for the thermocouple’s protective sheath. The ground connection helps to drain

any radio-frequency disturbances from the thermocouple before the signal enters the temperature controller or high

limit control module. For a temperature-sensing thermocouple, the ground lead MUST be connected to the ground

terminal on the temperature controller. For a high limit thermocouple, the ground lead should be connected to a

chassis ground or to the mounting screw for the high limit control module.

Some early thermocouples may have either two or four leads:
•

The two-lead thermocouple is simply an earlier version of the current model, without the ground lead. When replacing

a two-lead thermocouple, it will be necessary to connect the new ground lead.

•

The four-lead thermocouple is actually a dual-function unit which sends its signal to both the temperature controller

and the high limit control module. Current ovens use separate thermocouples for these functions. When replacing a

four-lead thermocouple, it will be necessary to use a SECOND KIT to install the high limit thermocouple. In addition,

any oven equipped with these early thermocouples should have all of its thermocouples updated at the same time. For

a PS570 or PS570S oven, this will require THREE THERMOCOUPLE KITS - two for the existing thermocouples, and

one for the new, separate high limit.

PS200 Series - before 2/96, serial numbers before ASH-0001 ........... 2
PS200 Series - 2/96 or later, serial numbers after ASH-0001 ............. 2
PS360 Series rear wall thermocouples - before 2/96, serial

numbers before ASH-0001 ................................................................. 3
PS360 Series rear wall thermocouples - 2/96 or later, serial

numbers after ASH-0001 .................................................................... 3
PS360 Series front-mounted thermocouples inside the

machinery compartment...................................................................... 4
PS536 ................................................................................................ 5

Oven Model

Page

PS555 Gas - rear wall thermocouples with screw terminal

connections (no terminal blocks) ......................................................... 8
PS555 Electric and PS555E ............................................................... 9
PS570 (X01-X05 name plate ID numbers) and PS570S

(early) with side-mounted thermocouples inside or outside

the blower motor compartments ........................................................ 10
PS570S (late) - rear wall thermocouples with left-side AND

right-side terminal block connections ................................................. 12
PS555G and PS570G - rear wall thermocouples with

left-side terminal block connections.................................................... 14

Oven Model

Page

KIT CONTENTS - KIT P/N 33985

P/N

Qty. Description

33812-2

1

Thermocouple, type J, 13-3/8” L

B301A8861

1

Screw, hex wshr hd #6 x 3/8”

34701

1

Instructions

WARNING

BEFORE PERFORMING ANY SERVICE WORK, THE ELECTRICAL POWER SUPPLY AND THE GAS SUPPLY MUST BE TURNED OFF.

D. Appendices

Appendix - Instructions for Service Kits 33984 and 33985 -

Oven Thermocouple Kit, 11/01

SECTION 3 - SERVICING COMPONENTS

Advertising
This manual is related to the following products: