Middleby Marshall PS200 series User Manual

Page 67

Advertising
background image

66

11

Figure 14a

Thermocouple Wiring - PS570S (Late) - Left to Right Conveyor

Red

(temp)

White

(temp)

Ground

leads

To temperature

controller

To high limit

control module

White

(hi lim)

Red

(hi lim)

Ground

leads (all)

White

(temp)

Red

(temp)

To mounting screw

for high limit

control module

To ground

terminal on temp

controller

To temperature

controller

To ground

terminal on temp

controller

Red

(temp)

White

(temp)

Ground

leads (all)

To temperature

controller

To high limit

control module

White

(hi lim)

Red

(hi lim)

Ground

leads

White

(temp)

Red

(temp)

To mounting screw

for high limit

control module

To ground

terminal on temp

controller

To temperature

controller

To ground

terminal on temp

controller

Figure 14b

Thermocouple Wiring - PS570S (Late) - Right to Left Conveyor

NOTE: This configuration

shows leads for three

t e m p e r a t u r e - s e n s i n g

thermocouples - two on the

left side, and one on the

right. Ovens with only two

t e m p e r a t u r e - s e n s i n g

thermocouples will have a

single set of leads on the

left terminal block, instead

of the two sets that are

shown.

NOTE: This configuration

shows leads for three

t e m p e r a t u r e - s e n s i n g

thermocouples - two on the

right side, and one on the

left. Ovens with only two

t e m p e r a t u r e - s e n s i n g

thermocouples will have a

single set of leads on the

right terminal block,

instead of the two sets

that are shown.

Left

Terminal

Block

Right

Terminal

Block

Left

Terminal

Block

Right

Terminal

Block

5. Install the new thermocouple into its mounting hole.

Fasten it in place with the supplied #6 x 3/8” screws.

6. Wire the thermocouple as shown in Figure 14. The

thermocouples should be wired to the terminal block

inside the blower motor compartment closest to the

thermocouple.

IMPORTANT
As you wire the thermocouples, check that ground leads

run from the terminal blocks inside the blower motor com-

partments to BOTH the temperature controller AND the

high limit control module, as shown in Figure 14.
If the ground leads to the front compartment of the oven

are NOT present - for example, on an oven that previ-

ously used the older-style 2-lead or 4-lead thermocouples

- it is acceptable to use a single chassis ground wire to

the mounting screw for the terminal block. See Figure

15.
A good ground connection for the thermocouple’s

uninsulated lead is REQUIRED for proper operation!

7. If you will be replacing additional thermocouples, re-

peat Steps 2-6 as necessary.

8. Use the kit-supplied nylon clamp and #10-16 x 3/4”

screw to secure the thermocouple leads so that they

will clear the shrouds, blower belts, and pulleys.

9. Close the machinery compartment and blower motor

compartment doors. Replace all shrouds onto the oven.

Figure 15

Alternate ground lead wiring

Use ONLY if ground leads to front compartment are not present.

To temperature

controller

To high limit

control module

White

(hi lim)

Red

(hi lim)

Ground

leads (all)

White

(temp)

Red

(temp)

New chassis

ground wire

Appendix - Instructions for Service Kits 33984 and 33985 -

Oven Thermocouple Kit, 11/01

SECTION 3 - SERVICING COMPONENTS