Middleby Marshall PS200 series User Manual

Page 48

Advertising
background image

47

B. INSTALLATION

WARNING

BEFORE PERFORMING ANY SERVICE WORK, THE GAS SUPPLY (IF SO EQUIPPED) AND

THE ELECTRICAL SUPPLY TO THE OVEN MUST BE TURNED OFF.

1. Open the machinery compartment and control compartment access panels.
2. Locate the high limit thermo bulb/capillary assembly. Its location is shown in Figure 2. Loosen the set

screw that holds the assembly in place. Remove the thermo bulb/capillary assembly from the mount-

ing tube.

3. Disconnect the wires (2 for the Type 54 control, 4 for the Type 55 control) from the terminals of the

United Electric control. Bundle the loose wires together, and allow them to hang loose for later

reconnection.

4. Remove the mounting screws that hold the United Electric high limit control in place. Then, remove

and discard the high limit control and its mounting screws.

5. Position the new high limit control in place on the left wall of the control compartment, as shown in

Figure 3. When positioning the control:
• Ensure that the control is positioned AT LEAST 1” (25mm) back into the compartment to allow the

compartment door to close.

• Ensure that additional space is left underneath the control for the reset switch.
NOTE: Instead of holding the high limit control in place, you may use the dimensions provided in

Figure 4 to determine the location of the control and its mounting holes.

6. Mark the locations of the two mounting holes for the high limit control. Then, drill the holes using a

3/16” drill bit.

7. Secure the high limit control in place using the kit-supplied 6-32 x 1-5/8” screws and 6-32 nuts.
8. Position the bracket for the reset switch on the left wall of the control compartment, as shown in Figure

3. Note that the face of the bracket with the large, circular switch-mounting hole should face YOU.

Also, the bracket should be positioned AT LEAST 3” (75mm) back into the compartment to allow the

door to close.

9. While holding the bracket in place, mark the locations of the two mounting holes. Then, remove the

bracket and drill the holes using a 3/16” drill bit.

10. Secure the bracket to the panel using the kit-supplied 6-32 x 1/4” screws and 6-32 nuts. DO NOT

INSTALL THE RESET SWITCH INTO THE BRACKET AT THIS TIME.

11. Insert the kit-supplied thermocouple into its mounting sleeve. Position the sleeve so that the mounting

hole is at the base of the thermocouple, not the tip. See Figure 5.

12. Insert the thermocouple and mounting sleeve into the original mounting tube. The set screw opening

in the sleeve should align with the set screw hole on the side of the mounting tube.
Push the thermocouple into the opening until its base seats firmly on the mount. See Figure 6.

13. Insert the thermocouple’s set screw into the hole on the side of the mounting tube. Tighten the set

screw to hold the thermocouple and sleeve in place.

14. Thread the thermocouple’s shielded cable into the electrical compartment. Coil the free end of the

cable and fasten it with the kit-supplied nylon wire tie. Be sure to leave enough free cable to reach the

new high limit control.

Page 2 of 8

SECTION 3 - SERVICING COMPONENTS

Appendix - Instructions for Service Kit 39733 -

High Limit Conversion Kit for PS300, 310, 350 & 360 Ovens, 5/99

Advertising