Middleby Marshall PS200 series User Manual

Page 65

Advertising
background image

64

9

Figure 12a

Thermocouple Wiring - PS570 and PS570S (early) after thermocouple update - Left to Right Conveyor

Figure 11

Location of New Thermocouple Mounting Holes - PS570, PS570S

Thermocouple positions

for Pizza Hut/Tricon ovens

Thermocouple positions

for non-Pizza Hut/Tricon ovens

High limit thermocouple

position for ovens with

LEFT-TO-RIGHT conveyors

High limit thermocouple

position for ovens with

RIGHT-TO-LEFT conveyors

Red

(temp)

White

(temp)

Ground

lead

To temperature

controller

To high limit

control module

White

(hi lim)

Red

(hi lim)

Ground

leads (all)

White

(temp)

Red

(temp)

To temperature

controller

Red

(temp)

White

(temp)

Ground

leads (all)

To temperature

controller

To high limit

control module

White

(hi lim)

Red

(hi lim)

Ground

lead

White

(temp)

Red

(temp)

To temperature

controller

Figure 12b

Thermocouple Wiring - PS570 and PS570S (early) after thermocouple update - Right to Left Conveyor

Left

Terminal

Block

Right

Terminal

Block

Left

Terminal

Block

Right

Terminal

Block

New chassis

ground wire

New chassis

ground wire

Appendix - Instructions for Service Kits 33984 and 33985 -

Oven Thermocouple Kit, 11/01

SECTION 3 - SERVICING COMPONENTS

Advertising