Scan types, Preparation, Scan speed – Icom IC-7700 User Manual

Page 136: Squelch condition

Advertising
background image

9-2

Scan types

• The scan function can be used on the main read-

out only.

• You can operate a scan while operating on a fre-

quency using the split functions.

PROGRAMMED SCAN

Repeatedly scans between two scan edge frequencies
(scan edge memory channels P1 and P2).

This scan operates in VFO mode.

SELECT MEMORY SCAN

Repeatedly scans all or one of 3 select memory channels.

F SCAN

Repeatedly scans within

F span area.

This scan operates in memory mode.

This scan operates in memory mode.

This scan operates in both VFO and memory modes.

Scan

Scan edge
P1 or P2

Scan edge
P2 or P1

Jump

MEMORY SCAN

Repeatedly scans all programmed memory channels.

Mch 1

1

Mch 5

1

Mch 2

2

Mch 3

1

Mch 4

Mch 6

3

Mch 7

1

Mch 99

1

Mch 1

1

Mch 5

1

Mch 2

2

Mch 3

1

Mch 4

Mch 6

3

Mch 7

1

Mch 99

1

Blank channel

Blank channel

Scan

Scan

F frequency

+

F frequency

Start frequency

Jump

*“

1,” “

2” and “

3” show that the channel

is specified as the select memory.

*“

1,” “

2” and “

3” show that the channel

is specified as the select memory.

9

SCANS

Preparation

• Channels
For programmed scan:
Program scan edge frequencies into scan edge mem-
ory channels P1 and P2.

For

F scan:

Set the

F span (

F scan range) in the scan screen.

For memory scan:
Program 2 or more memory channels except scan
edge memory channels.

For select memory scan:
Designate 2 or more memory channels as select mem-
ory channels. To designate the channel as a select
memory channel, choose a memory channel, then
push [F-3•SELECT] in the scan screen (memory
mode) or in the memory list screen.

• Scan resume ON/OFF
You can select the scan to resume or cancel when de-
tecting a signal in set mode. Scan resume ON/OFF
must be set before operating a scan. See p. 9-3 for
ON/OFF setting and scan resume condition details.

• Scan speed

Scan speed can be selected from 2 levels, high or low,
in scan set mode. See p. 9-3 for details.

• Squelch condition

SQUELCH

CLOSED

SQUELCH

OPEN

Scan stops when detecting a signal.

If you set scan resume ON in set mode, the
scan pauses for 10 sec. when detecting a
signal, then resumes. When a signal disap-
pears while scan is paused, scan resumes
2 sec. later.

The scan continues
until it is stopped
manually, and does
not pause even if it
detects signals.

Scan pauses on
each channel when
the scan resume is
ON; not applicable
when OFF.

SCAN

PROGRAMMED

STARTS

SCAN

MEMORY SCAN

WITH

Advertising