Dcommand table (continued), Control command – Icom IC-7700 User Manual

Page 192

Advertising
background image

14-5

D

D

Command table (continued)

14

CONTROL COMMAND

1A

050023

Send/read CW side tone gain
(0=min. to 255=max.)

050024

Send/read CW side tone gain limit
(0=OFF, 1=ON)

050025

Send/read beep gain
(0=min. to 255=max.)

050026

Send/read beep gain limit
(0=OFF, 1=ON)

050027

Send/read headphones output
ratio (0=0.60 to 255=1.40)

050028

Send/read AF output level to ACC
(0=0% to 255=100%)

050029

Send/read S/P DIF output level
(0=0% to 255=100%)

050030

Send/read MOD output level to
ACC (0=0% to 255=100%)

050031

Send/read S/P DIF MOD output
level (0=0% to 255=100%)

050032

Send/read MOD input connector
during DATA OFF (0=MIC;
1=ACC; 2=MIC/ACC; 3=S/P DIF)

050033

Send/read MOD input connector
during DATA1
(0=MIC; 1=ACC; 2=MIC/ACC;

3=S/P DIF)

050034

Send/read MOD input connector
during DATA2
(0=MIC; 1=ACC; 2=MIC/ACC;

3=S/P DIF)

050035

Send/read MOD input connector
during DATA3
(0=MIC; 1=ACC; 2=MIC/ACC;

3=S/P DIF)

050036

Send/read relay type selection
(0=Lead, 1=MOS-FET)

050037

Send/read external meter output
selection
(0=Auto, 1=S, 2=Po, 3=SWR,

4=ALC, 5=COMP, 6=V

D

, 7=I

D

)

050038

Send/read external meter output
level (0=0% to 255=100%)

050039

Send/read reference signal in/out
setting (0=OFF, 1=IN, 2=OUT)

050040

Send/read reference signal fre-
quency setting
(0=0% to 255=100%)

050041

Send/read LCD unit backlight
brightness (0=0% to 255=100%)

050042

Send/read switch indicator bright-
ness (0=0% to 255=100%)

050043

Send/read screen image type
(0=A, 1=B)

050044

Send/read frequency readout font
(0=Basic (1), 1=Basic (2), 2=Italic,

3=Round, 4=Slim)

050045

Send/read meter response setting
(0=SLOW, 1=MID, 2=FAST)

050046

Send/read meter type
(0=Standard, 1=Edgewise, 2=Bar)

050047

Send/read meter type during wide
screen or mini scope indication
(0=Edgewise, 1=Bar)

050048

Send/read peak hold set for Bar
meter (0=OFF, 1=ON)

1A

050049

Send/read memory name indica-
tion setting (0=OFF, 1=ON)

050050

Send/read audio peak filter width
pop-up indication setting
(0=OFF, 1=ON)

050051

Send/read manual notch width
pop-up indication setting
(0=OFF, 1=ON)

050052

Send/read screen saver set
(0=OFF, 1=15 min., 2=30 min.,

3=60 min.)

050053

Set/read screen saver type
(0=Bound, 1=Rotation, 2=Twist)

050054

Send/read output signal setting for
external display (0=OFF, 1=ON)

050055

Send/read synchronous pulse
level setting (0=L, 1=H)

050056

Send/read opening message indi-
cation (0=OFF, 1=ON)

050057

Send/read opening message con-
tents (see p. 14-9 for details)

050058

Send/read date
(20000101=1st Jan. 2000 to
20991231=31st Dec. 2099)

050059

Send/read time
(0000=00:00 to 2359=23:59)

050060

Send/read CLOCK2 function
(0=OFF, 1=ON)

050061

Send/read offset time for CLOCK2
(240001=–24:00 to

240000=+24:00)

050062

Send/read CLOCK2 name
(up to 3-character; see p. 14-9)

050063

Send/read calibration marker
(0=OFF, 1=ON)

050064

Send/read confirmation beep
(0=OFF, 1=ON)

050065

Send/read band edge beep
(0=OFF, 1=ON)

050066

Send/read beep audio frequency
(50=500 Hz to 200=2000 Hz)

050067

Send/read quick split set
(0=OFF, 1=ON)

050068

Send/read FM split offset –9.999
to +9.999 MHz for HF
(see p. 14-10 for details)

050069

Send/read FM split offset –9.999
to +9.999 MHz for 50 MHz
(see p. 14-10 for details)

050070

Send/read split lock set
(0=OFF, 1=ON)

050071

Send/read tuner auto start set
(0=OFF, 1=ON)

050072

Send/read PTT tune set
(0=OFF, 1=ON)

050073

Send/read transverter set
(0=OFF, 1=ON)

050074

Send/read transverter offset
(see p. 14-10 for details)

050075

Send/read RTTY mark frequency
(0=1275 Hz, 1=1615 Hz,

2=2125 Hz)

050076

Send/read RTTY shift width
(0=170 Hz, 1=200 Hz, 2=425 Hz)

Command

Sub command

Description

Command

Sub command

Description

Advertising