5-2

Spectrum scope screen

This DSP-based spectrum scope allows you to display
the conditions on the selected band, as well as relative
strengths of signals. The IC-7700 has two modes for
the spectrum indication— one is center mode, and an-
ther one is fixed mode.

In addition, the IC-7700 has a mini scope screen to
save screen space.

D

D

Center mode

Displays signals around the set frequency within the
selected span. The set frequency is always displayed
at the center of the screen.

q

Push

several times to close a multi-func-

tion screen, if necessary.

w

Push [F-1•SCOPE] to select the scope screen.

e

Push [F-5•CENT/FIX] to select the center mode.

• “

” is displayed when center mode is selected.

r

Push [F-1•SPAN] several times to select the scope
span.

• ±2.5, ±5.0, ±10, ±25, ±50, ±100 and ±250 kHz are avail-

able.

• Push and hold [F-1•SPAN] for 1 sec. to return to ±2.5

kHz span.

• Sweeping speed is selectable for each span indepen-

dently in scope set mode. (pgs. 5-5, 5-6)

t

Push [F-2•ATT] several times to activate an attenu-
ator or turn the attenuator OFF.

• 10, 20 and 30 dB attenuators are available.
• Push and hold [F-2•ATT] for 1 sec. to turn OFF the at-

tenuator.

y

Push [F-3•MARKER] to turn the marker for transmit
frequency ON or OFF.

• “

” displays the marker at the transmit frequency.

• “<<” or “>>” appears when the marker is out of range.
• The spectrum scope shows the transmit signal wave-

form while transmitting. This can be deactivated in
scope set mode. (p. 5-5)

• The spectrum scope shows the peak level holding func-

tion. Peak levels are displayed in the background of the
current spectrum in a different color until the receive fre-
quency changes. This can be deactivated and the wave-
form color can be set in scope set mode. (p. 5-5)

u

Push [F-4•HOLD] to freeze the current spectrum
waveform.

• “

” appears while the function is in use.

• The peak hold function can be deactivated in scope set

mode.

i

Push

to exit the scope screen.

NOTE: If a strong signal is received, a ghost wave-
form may appear. Push [F-2•ATT] several times to
activate the spectrum scope attenuator in this case.
Spurious signal waveforms may be displayed. They
are generated in the internal scope circuit and do
not indicate a transceiver malfunction.

EXIT/SET

HOLD

T

CENTER

EXIT/SET

F-2

ATT

F-4

HOLD

F-1

SPAN

F-3

MARKER

F-5

CENT/FIX

EXIT/SET

5

FUNCTIONS FOR RECEIVE

• Observed indication example