Remote jack (ci-v) information, Dci-v connection example, Ddata format – Icom IC-7700 User Manual

Page 189

Advertising
background image

14-2

Remote jack (CI-V) information

D

D

CI-V connection example

The transceiver can be connected through an optional
CT-17

CI

-

V LEVEL CONVERTER

to a PC equipped with an

RS-232C port. The Icom Communications Interface-V
(CI-V) controls the transceiver.

Up to 4 Icom CI-V transceivers or receivers can be
connected to a PC equipped with an RS-232C port.
See p. 12-17 for setting the CI-V condition using set
mode.

D

D

Data format

The CI-V system can be operated using the following
data formats. Data formats differ according to com-
mand numbers. A data area or sub command is added
for some commands.

Controller to IC-7700

FE FE

74

E0

Cn

Sc

Data area

FD

Preamble

code

(fixed)

Transceiver’s

default address

Controller’s

default address

Command number

(see the command table)

Sub command number

(see command table)

BCD code data for

frequency or memory

number entry

End of message

code

(fixed)

OK message to controller

FE FE

E0

74

FB

FD

FE FE

E0

74

FA

FD

Preamble

code

(fixed)

Controller’s

default address

Transceiver’s

default address

OK code

(fixed)

End of message

code

(fixed)

NG message to controller

NG code

(fixed)

IC-7700 to controller

q

w

e

r

t

y

u

FE FE

E0

74

Cn

Sc

Data area

FD

q

w

e

r

t

y

u

personal
computer

ct- 17

IC-7700

9–15 V DC

mini-plug cable

14

CONTROL COMMAND

Advertising