Protection concept

The following parameters are monitored

continuously and in parallel by the micro-

controller and displayed on the screen:

· AFI error (ground fault)

· Overheating of the cooling element

· DC

overvoltage

· AC

undervoltage/overvoltage

In the event of a fault, the conversion is

immediately blocked and the grid relay

disconnected.

In addition, the following protective devi-

ces are provided on both grid and PV

generator side:

· Grid-side varistors

Protect the power semiconductors from

high-energy, time-limited voltage spikes on

the grid and provide for a reduction of

energy in the throttle in the event of grid

disconnection.

· Generator-side varistors

Thermally monitored varistors provide pro-

tection against atmospheric overvoltages

(e.g. due to remote strikes during storms).