Data memory

Your solar inverter is equipped with an

internal data memory as standard. This

data memory provides you with a detailed

view of the mode of functioning and the

relevant values of your solar power supply

at all times. You can access these data

with the help of the NT Monitor software

described below. The following measured

values can be determined:

· DC voltage

· AC voltage and AC current (power calcu-

lation)

· Irradiation and module temperature

(if a sensor is connected)

· Time and date

The following values can be accumulated,

stored and successively overwritten:

· 15 minute values for AC current, DC and

AC voltages, irradiation and temperature

· 120 times storage of 15-minute average

values in the recirculating storage;

storage depth: three days on average,

then overwriting of values

· Storage of accumulated daily work in

Wh and of 40 daily values in the recircu-

lating storage and successive overwriting

of values

· Storage of accumulated monthly work in

kWh and of 13 monthly values in the

recirculating storage, then overwriting

of values

· Storage of faults with max. ten values,

then successive overwriting of values

Please note that all displayed performance

data are displayed with a nominal measu-

ring accuracy of maximum 5 %. The energy

counter of your EVU should be used as

absolute reference for the fed-in energy.