127

3.4 Fault

diagnosis

Fault display

Overtemperature

UDC

Overvoltage

Causes

The maximum permissible

ambient temperature of

40°C has been exceeded.

The necessary air circulation

was not taken into account

during installation.

Objects have been stored on

the heat sink, impeding free

convection.

The maximum DC voltage

has been exceeded.

Too many modules are con-

nected in series.

Remedies

The installation location is not suitable.

Please find another installation location.

Clean the solar inverter if dirt is

impeding the cooling unit.

Remove the objects.

Check the dimensioning of your

PV generator.

Reduce the number of modules and

re-commission the system.