Sunway NT 2600 User Manual

Page 21

Advertising
background image

97

EN

PV generator connection

· Preparation

Execute the DC cabling according to your

electrician's system dimensioning. Check

each PV string for correct functioning

by performing a no-load voltage current

and short-circuit current measurement.

To achieve the necessary protection

against hazardous contact voltage during

the installation of PV systems, the positi-

ve and negative conductors must be kept

separate from the ground potential (PE).

Contactable, conductive parts of the PV

generator (e.g. metal frame, supporting

structure etc.) must be earthed (connec-

ted to PE).

Check that the generator is free from

ground faults.

Make the electrical connection to the

solar inverter.

!

· Connection

The PV generator is connected via the

externally accessible, shock-proof TYCO

SOLARLOK connectors, which are enclosed

with the delivery. The TYCO SOLARLOK

connectors are designed for a cable cross-

section of 4 mm2 and must be crimped

(see data sheet and connector assembly

with TYCO crimping tool on page 144).

Connect the two right DC female connectors

with «+», the two left DC female connectors

with «-» of the PV generator (see figure

below).