(3) PV system for 2 to 99 solar inverters with interface converter (I C)

Connection to PC via RS 485 / RS 232

In order to connect several solar inverters to a
PC, the RS 485 signal is looped through from
inverter to inverter, until it is led into the inter-
face converter. From here, the RS 232 signal is
conducted to the PC. Jumper JP400 is connected
to the solar inverter that is furthest away
from the interface converter. It must be open
for all other solar inverters.

Stripped length: 11 mm
Jumper JP400: see above

(3) Up to 99 solar inverters can be con-

nected together and read out using this

connection. In this case, there is a maxi-

mum cable length of 500 m between

117

PC

I C

INVER

TER

(2 to 99)

INVER

TER

(1)

PV

PV

RS 232

RS 485

RS 485+

RS 485+

RS 485–

RS 485–

GND_G

TX

RX

GND_G

TX

2

RX

2

RS 485+

RS 485+

RS 485–

RS 485–

the interface converter and the furthest

solar inverter. The individual solar inverters

are connected together via the RS 485

interface.