119

RS 485+

RS 485+

RS 485–

RS 485–

GND_G

TX

RX

GND_G

TX

2

RX

2

RS 485+

RS 485+

RS 485–

RS 485–

Connection to modem via RS 485 / RS 232

In order to connect several solar inverters to
the remote monitoring, the interface converter
is connected directly to a modem via RS 232.
Jumper JP400 is connected to the solar inverter
that is furthest away from the interface conver-
ter. It must be open for all other solar inverters.

Stripped length: 11 mm
Jumper JP400: see above

(4) If several solar inverters are to be con-

nected to the remote inquiry, then the

individual inverters are connected together

by means of the RS 485 signal, as when

reading out several units locally. This signal

is converted by the interface converter

into the RS 232 signal, from where it is led

to the modem using cable type C. Jumper

JP400 must be closed at the solar inverter

that is furthest away from the interface

converter. For all other solar inverters it

must be open. An address must be alloca-

ted, to enable identification of the indivi-

dual solar inverters. This is described in

Chapter 2.3 Commissioning, under

«Configuration».