Sunway NT 2600 User Manual

Page 26

Advertising
background image

102

Connecting the sensors

· Optional irradiation sensor

The optional addition of an irradiation

sensor (type Si-01TC-T from Ing.-Büro

Mencke & Tegtmeyer ) with integrated

PT-100 temperature sensor for tempera-

ture measurement enables recording of

the irradiation data and the correspon-

ding module temperature in the cycle

of the internal data memory.

This additional measuring unit helps with

analysis of the system. On the basis of the

values, possible errors in the PV generator,

such as e.g. shading or failure of solar cells,

can be detected.

For demonstration purposes, the irradia-

tion sensor and the corresponding data

can be used to show how a PV system

functions. In conjunction with the

Sunways NT Monitor visualisation soft-

ware, the stored data can be displayed.

!

Before you connect an irradiation sensor,

you must remove the cover of the solar

inverter. Pay heed to all safety hints on

pages 90 and 91. Please note that the

inputs and outputs are not short-circuit

resistant.

The optional irradiation sensor with

temperature sensor is connected to the

corresponding terminals at the bottom

right of the middle board.

(Top figure) Connection block for

temperature sensor cables with the signals:

Temp, Solar, V+ and V-.

Advertising