3.3 Fault

indications

Your solar inverter operates fully automati-

cally and maintenance-free. However, if

operational faults occur due to external or

internal causes, these will be displayed on

the screen.

· AC over/undervoltage (3-phase)

Your solar inverter monitors the limits of

minimum and maximum permissible

3-phase grid voltage. If these limits are

exceeded (Umin = 184 V, UN = 230 V,

Umax = 264 V), the solar inverter will switch

off and will only start up again when the

voltage value is within the limits. The

fault cut-out can be triggered even by very

brief overvoltages and undervoltages.

Display for AC overvoltage:

125

EN

Line 1

Error: UAC_3

Line 2

Overvoltage

Display for AC undervoltage:

· AC over/undervoltage (1-phase)

Your solar inverter monitors the limits of

minimum and maximum permissible grid

voltage in the feed-in phase. If these limits

are exceeded, the solar inverter will switch

off and will only start up again when the

voltage value is within the limits.

Display for AC overvoltage:

Display for AC undervoltage:

Line 1

Error: UAC_3

Line 2

Undervoltage

Line 1

Error: UAC_1

Line 2

Overvoltage

Line 1

Error: UAC_1

Line 2

Undervoltage