Display for AFI error protection:

· Overheating fault

Your solar inverter is designed for an

ambient temperature of up to +40°C.

When the maximum upper temperature

threshold is reached, the feed-in is stop-

ped. When the heat sink temperature

has decreased, the solar inverter starts

up again automatically.

126

· DC overvoltage

A maximum no-load voltage of 750 V is

permitted for the PV generator.

All components of the DC input are ade-

quately dimensioned with a safety factor.

If the threshold is exceeded, the solar

inverter stops the feed-in and a «DC over-

voltage error» is displayed.

Display for DC overvoltage:

· AFI residual current

The AFI residual current (insulation error,

ground fault) is displayed if a residual

current has occurred in the PV system and

the solar inverter has subsequently discon-

nected from the grid. Ground faults are

monitored on both the AC and DC side

(universal current-sensitive FI). If this error

message is displayed, the entire PV system

must be checked for insulation errors. The

AFI residual current operated device only

monitors the phase into which feed-in

occurs.

Line 1

Error: UDC

Line 2

Overvoltage

Line 1

Error: AFI

Line 2

Residual current

Line 1

Error: TEMP

Line 2

Overtemperature