· Sensor interface

An irradiation sensor with integrated

temperature sensor can be optionally con-

nected to the relevant interface. This

allows first time users to quickly grasp the

mode of functioning of their PV system,

and facilitates monitoring of the PV

system for professionals.

· AFI universal sensitive residual current

device

The universal (DC and AC) sensitive residu-

al current device (AFI) monitors the solar

system for residual currents. To do this,

it disconnects the solar inverter from the

grid by means of a relay as soon as a resi-

dual current occurs on the PV generator

side or on the AC side in the solar inverter.

After cutoff by the relay and as soon as

the residual current has stopped, the AFI

automatically attempts to reconnect the

solar inverter to the grid. The AFI of the

Sunways solar inverter complies with

standard DIN V VDE V 0126-1-1.

In addition, the AFI of Solar Inverters NT

2600, NT 4000 and NT 6000 has an absolu-

tely time-independent effective value

136

· Grid protection

The grid protection is a powerful relay

which ensures reliable grid disconnection

in the case of error and for night switch-

off. This relay fulfils the requirement for

trouble-free grid disconnection.

· Microcontroller

As well as system management, the

efficient microcontroller undertakes

additional tasks, such as saving data

and communication.

· LCD display

Important information for the operator

about the system operation and status is

displayed on an LCD display of 2 x 16

characters.

· RS 485 and RS 232 interfaces

The two RS 485 and RS 232 interfaces

installed as standard serve for communi-

cation with the solar inverter and the PV

system. The system can be visualised via

the Sunways NT Monitor software.