Chapter 9

Managing the SAN

123

To Rezone a Sun StorEdge T3 Array to Host B

1. If necessary, configure all paths to the Sun StorEdge T3 array using the

cfgadm -

c configure

command.

This will create device nodes. Perform this step if the Sun StorEdge T3 array is
connected in a name server zone and is accessed by a host port connected to a
switch F-port. For additional information, refer to “Creating On-Demand Device
Nodes on Hosts for Fabric Configurations” on page 89
of Chapter 8

2. Import any Volume Manager disk groups.

3. Mount any existing file systems available on the Sun StorEdge T3 LUNs or disk

groups.

Adding Storage Devices

This section contains the following topics:

“Adding a Sun StorEdge A5200 Array” on page 123

“Adding a Sun StorEdge T3 Workgroup or Enterprise Array” on page 124

“Adding a Sun StorEdge A3500FC Array” on page 124

“Adding a FC-Tape Drive” on page 124

Adding a Sun StorEdge A5200 Array

You can only add Sun StorEdge A5200 arrays to a SL zone.

Use the

luxadm insert_device

command to hot swap a new disk drive,

enclosure, or chain of enclosures. If you specify more than one enclosure, you can
perform concurrent hot swapping on multiple buses.

The

insert_device

command interactively guides you through the hot swapping

of one or more devices. For further information, see the

luxadm

(1M) man page.

In the disk array, the

insert_device

command performs the following functions:

Sends notice when the device can be safely inserted

Requests confirmation that the list is as expected

Creates the logical device names for the new devices

Displays the logical path name for the devices

Advertising