Problem, Corrective measures – Sun Microsystems FC Switch-8 and Switch-16 816-0830-12 User Manual

Page 166

Advertising
background image

136

Sun StorEdge Network FC Switch-8 and Switch-16 Installation and Configuration Guide • October 2001

Corrective Measures

Using the SANsurfer GUI, verify that the zoning is correct.

Using the SANsurfer GUI, check that the port configuration is correct.

Fabric Mode

Sun Storage T3 is configured on TL_Port

HBA is configured on F_Port (point-to-point only)

Segmented Loop Mode (private loop)

Storage is configured on SL-Ports

HBA is configured on SL-Ports

HBA and storage are configured in the same SL-Zone

Make sure Sun StorEdge T3 or Sun StorEdge A3500FC LUNs are properly
initialized and mounted.

Check the

cfgadm

listing for Fabric-connected ports (only for the Sun StorEdge

T3 Array in Fabric mode).

Are Fabric-connected Sun StorEdge T3 arrays listed as configured and in normal
condition?

Refer to the

cfgadm_fp(1M)

man page for information on configuring and

checking conditions).

Check

/var/adm/messages

for any errors reported during configuration.

Run

devfsadm -C

. This removes stale device nodes, which belong to removed

devices.

Check Network Storage Agent for messages or events.

Run Stortools Functional or Expert Tests to verify or isolate suspect links.

If the problem persists, contact your Sun Service representative

Problems and Corrective Measures—Sun
StorEdge Traffic Manager

Problem

You cannot see Sun StorEdge Traffic Manager devices with the software installed.