Fc tape libraries – Sun Microsystems FC Switch-8 and Switch-16 816-0830-12 User Manual

Page 41

Advertising
background image

Chapter 2

Configurations

11

Sun StorEdge Network FC Switch-8

Sun StorEdge Network FC Switch-16

Note –

Make sure the switch chassis ID is not 0. You can change the chassis ID in

the Switch Faceplate Display window. After changing the chassis ID, click the Apply
button. For more information on the chassis ID, refer to the SANbox-8/16 Switch
Management User’s Manual for Sun StorEdge Network FC switch 3.0.

FC Tape Libraries

You can configure either the Sun StorEdge L180 or L700 Tape Library with a switch.

The switch may be zoned to allow up to four hosts per zone

You can configure a maximum of three Storage Tech (STK) 9840FC drives per
zone

A library may share a zone with up to three drives

A single zone cannot have more than one tape library