Service Manual 15

Part 2 Functions & Controls

4.6 Sleep mode Auto control

• When the set sleep time is reached set time of [1,2,3,4,5,6,7hour] input by the remote control during the operation, the

operation of the appliance stops.

• When the appliance is on pause, the sleep timer mode cannot be input.

4.6.1 Sleep timer operation for cooling cycle

• While in cooling mode , 30 min. after the start of the sleep timer, the setting temperature increases by 1 C(2

.

After another 30minutes lapse, it increases again by 1°C(2

.

4.6.2 Sleep timer operation for heating cycle

• While in heating mode, 60 min. after the start of the sleep timer, the setting temperature decreases by 1 C(2

.

After another 60minutes lapse, it decreases again by 1°C(2

.

4.7 Auto restart

• When the power comes back after a sudden power failure during operation, the mode before the power failure is kept

on the memory of the appliance and it automatically operates in the saved mode on the memory.

• Operation mode that is kept on the memory

- State of operation ON/OFF
- Operation mode/setting temp./selected airflow speed
- Sleep timer mode/remaining time of sleep timer
- Chaos Swing

Setting temp. (˚C)

1.0˚C(2˚F) up

1.0˚C(2˚F) up

Cooling ON temp.
(Setting temp. +0.5˚C(+1˚F))

Cooling OFF temp.
(Setting temp. -0.5˚C(-1˚F))

0.5

1

Sleep time (hour)

Setting temp. (

°C)

Heating ON temp.
(Setting temp)

Heating OFF temp.
(Setting temp. +4.0

°C(+8°F))

1

2

Sleep time (hr)

1.0

°C(2°F) down

1.0

°C(2°F) down