5.12 Low Ambient control

5.12.1 9,12kBtu/h Model

• If outdoor temperature drops below certain temperature, liquid back is prevented by reducing fan speed.

• It can prevent frosting of evaporator and keep cooling operation

• No matter even if the outdoor temperature reaches -10°C(14°F).

• You can Cool your room at your desired temperature all year around.

Freq.

0

°C(32°F)

°…

Outdoor temp.

Outdoor pipe temp.
0

°C outdoor fan On/Off

control

°

Comp Freq.

Outdoor fan

On

On

Off

Off

Outdoor temp.:-10

°C(14°F)

-5(23

°F)

0(32

°F)

5(41

°F)

10(50

°F)

15(59

°F)

20(68

°F)

25(77

°F)

0

50

100

150

200

Time(Min.)

Temp.(

°C)

Outdoor fan On/Off control

Cond . temp.

5.12.2 18, 24, 30kBtu/h Model

Low ambient cooling case : In this situation outdoor fan works in ON/OFF control.

: If the pipe temperature 0°C(32°F) and it is falling rapidly in that case compressor will run for 5 min & then it will

go in low ambient control. (

❈ Temp. value can be different for each model.)

❈ After the system is stopped by CT cut or heat sink cut-off then the cycle returns to the normal condtiond control.

(T1 = 0)

°C

(T2 = 0)

°C

Outdoor pipe temp

O/D fan

Set speed

Off

Off

Set speed

Set speed

Advertising