Service Manual 63

Part 4 Trouble Shooting

8) Troubleshooting CH32, CH33, CH40

LEV Openness

(Pulse)

COMP Frequency

(Hz)

Toff(105)

°C

T1(90)

°C

T2(95)

°C

OFF

Normal

OFF Control

Normal

Normal

Normal

D-Pipe temp.

(221)

°F

(194)

°C

(203)

°C

32

33

40

D-pipe (Inverter)

temp. high

(105°C(221°F)

)

D-pipe (Constant)

temp. high

(105°C(221°F)

)

CT Sensor

• Discharge sensor

(Inverter) temp. high

• Discharge sensor

(Cons.) temp. high

• Open/Short
• Soldered poorly
• Internal circuit error

• Check the discharge pipe sensor for INV.
• Check the install condition for over load.
• Check the leakage of refrigerant.
• Check the SVC V/V open.

• Check the discharge pipe sensor for Cons.
• Check the install condition for over load.
• Check the leakage of refrigerant.
• Check the SVC V/V open.

• Normal resistor : about 0

Error

code

Title

Cause of error

Check point & Normal condition

Check Point

• CH 32

1. Check the install condition for over load.

2. Check the SVC V/V open.

3. Check the leakage of refrigerant.

• CH 40

1. If the resistance of the sensor is only

, the check Is

possible.

2 If the error occurs again after the reset , change the

PCB.

• CH 33

1. Check the install condition for over load.

2. Check the SVC V/V open.

3. Check the leakage of refrigerant.

4. Check the constant compressor. (same with CH21)