20 Room Air Conditioner

Part 2 Functions & Controls

5.6 Power Relay Control

• Power relay turns on 1 second later after the power is supplied to the outdoor unit.

• Control sequence : power on

→ PTC operating → power relay on

5.7 Inverter

1. The single phase power AC is converted into DC.

2. The single phase power DC is converted into a three phase chopped DC voltage with a variable frequency.

3. When the frequency changes, the rotation speed of the compressor changes resulting in an changed refrigerant circu-

lation. This leads to changeable amount of the heat exchange per unit.

Comp.
Motor

U

U V W

V

W

+