Check point – LG General Wall Mounted-Inverter Type User Manual

Page 61

Advertising
background image

Service Manual 61

Part 4 Trouble Shooting

6) Troubleshooting CH24, CH25

CN TRNAS1

CN PRESS

TRANS1

50Hz, DC12V

24

25

Press S/W Open

Input voltage

• Low / High press

S/W open.

• Abnormal Input voltage

(140VAC , 300VAC ).

• Check the connection of “CN_Press”.
• Check the components.

• Check the power source.
• Check the components.

Error

code

Title

Cause of error

Check point & Normal condition

Check Point

• CH 24

1. Check the connection of “CN_PRESS”

2. Check the install condition for over load.

3. Check the SVC V/V open.

4. Check the leakage of refrigerant.

• CH 25

1. Check the power source.

2. Check the components

(Trans1, B/Diode, Diode, Resistance)

Advertising