Trouble 5 – LG General Wall Mounted-Inverter Type User Manual

Page 45

Advertising
background image

Service Manual 45

Part 4 Trouble Shooting

When indoor Fan does not operate.(9~30kBtu/h Model)

Trouble 5

Check the SSR high speed operation by remote control.

(the Indoor Fan Motor is connected)

Turn off main power.

Check the connection of CN-FAN.

Check the Fan Motor.

Check the Fuse(AC250V, T2A).

Turn on the main power

Check the related circuit of indoor Fan Motor.

• The pin No.

38

of micom and the part for driving SSR.(Q01M)

• Check the related pattern.
• Check the SSR.

- SSR Open: Indoor Fan Motor never operate.
- SSR short: Indoor Fan Motor always operates in case of ON or OFF.

The voltage of Pin No 1(orange) and 3(black) of CN-FAN.

About AC 160V over

About AC 50V over

SSR is not damaged

Check SSR