Outdoor error – LG General Wall Mounted-Inverter Type User Manual

Page 47

Advertising
background image

Service Manual 47

Part 4 Trouble Shooting

18,24,30kBtu/h Model
Indoor Error

00

No Error

ON

01

Indoor Room themistor error

1time

OFF

02

Indoor in-piping sensor error

2times

OFF

03

Remote controler error

3times

OFF

04

Drain Pump error

4times

OFF

05

Communcation error between in and out

5times

OFF

06

Indoor Out-Piping sensor error

6times

OFF

07

Diffrent mode operation

times

OFF

Outdoor Error

Ex) Error Code 21 (IPM Fault)

1 Time

1 Time

1 Time

2 Times

2 Times

2 Times

1 Sec.

2 Sec.

2 Sec.

1 Sec.

1 Sec.

LED01G

(RED)

LED02G

(GREEN)

Case of error

LED02G

(Green)

LED01G

(Red)

Contents

Error

code

Compressor malfunction,IPM Fault

Current is 14A

DC Link volt. Is 140V

Low / High press switch OPEN

Abnormal AC volt. Input.

Off

Off

Off

IPM Fault (Compressor Over current)

CT 2(Max. Current)

DC Link Low Volt.

Low / High press

AC Low / AC High Volt.

DC Compressor Position

PSC Fault

DC Link High Volt

Discharge Pipe Temp. High (INV)

Discharge Pipe Temp. High (Cons.)

21

22

23

24

25

26

27

28

32

33

Off

Off

Off

Off

Off

Off

Off

Off

Off

Off

Outdoor

Status

2 times

2 times

2 times

2 times

2 times

2 times

2 times

2 times

3 times

3 times

1 time

2 times

3 times

4 times

5 times

6 times

7 times

8 times

2 times

3 times

Error code

Descrition

INV TPS

LED1

LED2

Indoor

(Red)

(Green)

Status