Service Manual 53

Part 4 Trouble Shooting

7

• Supplied power is not normal
• Indoor/outdoor fan is locked
• Too much refrigerant
• Defect in current sensing circuit in outdoor pcb assembly

Over current Error

(CT2)

Supplied voltage to
Outdoor pcb is about
AC 208~230V ?

Does indoor / outdoor fan work
normally ?

YES

No

Check power source

No

Check indoor / outdoor fan and
adjust.

Check flow

Refrigerant pressure is right ?

YES

No

Check refrigerant pressure
and adjust.

Current sensing circuit is right ?

YES

No

Check current sensing circuit.
- check CT is damaged in outdoor pcb

(output wire is disconnected to pin or not)

- BD01N is inserted in right position

(refer marking on pcb and component)

- Spec of R01N (1k

Ω), R02N (1.65kΩ) is correct

- Direction of diode (D01N, D02N) is right

Description

Cause of error

Error code