Panasonic WJ-HD309 User Manual

Page 146

Advertising
background image

146

Item

Start sequence

Stop sequence

Disk selection

Marking

Alarm Control

Item

Alarm input

Alarm input with text

Alarm reset

Alarm suspension

Alarm change information
(LED indication)

Alarm change information

Setup Control

Item

Display SETUP MENU

Transmission command (ASCII)

MSU:n

DCR:n1n2

TSU:yyyymmddhhnn

MST:n

MRM:n

Response command (ASCII)

MSU:n

DCR

TSU

MST

MRM

Parameter (ASCII)

n=0 SETUP MENU OFF
n=1 SETUP MENU ON

n1n2=A1 Right
n1n2=C1 Upward
n1n2=E1 Left
n1n2=G1 Downward
n1n2=+1 Increment parameter (+)
n1n2=-1 Decrement parameter (–)
n1n2=PD Move to virtual menu (SET)
n1n2=P- Go back to an older page (BACK)
n1n2=PU Move to upper layer (ESC)

yyyymmddhhnn: Date and time

n=0 Standard time n=1 Summer time

n=0 Normal recording mode
n=2 Continuous (External timer) recording

mode

Transmission command (ASCII)

OQT:01F

OQS:0

ZDS:k

ZMP

Transmission command (ASCII)

OAI:b

1

b

2

b

3

a

1

a

2

a

3

a

4

ZAI:b

1

b

2

b

3

a

1

a

2

a

3

a

4

:

nn:ddd...ddd

OAL;n

MAD:n

Response command (ASCII)

OQT:01F:01

OQS

ZDS:k

ZMP

Response command (ASCII)

OAI

ZAI:nn

OAL

MAD:n

ALD:n

ALM: b

1

b

2

b

3

a

1

a

2

a

3

a

4

Parameter (ASCII)

b

1

b

2

b

3

: Head alarm CH information (binary)

a

1

a

2

a

3

a

4

: Alarm CH information (binary)

b

1

b

2

b

3

: Head alarm CH information (binary)

a

1

a

2

a

3

a

4

: Alarm CH information (binary)

nn=01 - 99 (Sequence No)
ddd...ddd: text (200 bytes or less)

n=0 Alarm all reset
n=1 Alarm reset

n=0 Alarm suspension OFF
n=1 Alarm suspension ON)

n=0 LED OFF
n=1 LED ON
n=2 LED Blinking

b1b2b3: Head alarm CH information (binary)
a1a2a3a4: Alarm CH information (binary)

Parameter (ASCII)

k=0 HDD normal/event recording sector
k=1 HDD copy sector
k=2 Disk connected to COPY 1
k=3 Disk connected to COPY 2)

Electronic zooming

OZM:m

OZM:n

m=0 Electronic zooming OFF
m=1 Electronic zooming ON
m=> Switch x2 -> x4
m=< Switch x4 -> x2
m=+ Switch Electronic zooming OFF -> x2 ->
x4 -> Electronic zooming OFF -> ...
m=- Switch x4 -> x2 -> Electronic zooming OFF
-> x4 -> ...
n=0 Electronic zooming OFF
n=2 x2
n=4 x4 term

Move cursor

Date & Time setup

Summer time setup

Recording mode setup

Login/Logout

Item

Login

Logout

Transmission command (ASCII)

OLI:uuu...uuu:
ppp...ppp

OLO

Response command (ASCII)

OLI:n

OLO

Parameter (ASCII)

uuu...uuu: User name (32-byte fixed length)
ppp...ppp: Password (32-byte fixed length)
n=0 Error in user name/password
n=1 Login succeeded
n=2 Login failed

Advertising