Pin array – Panasonic WJ-HD309 User Manual

Page 83

Advertising
background image

83

How to Use the Terminals of the ALARM/CONTROL Connector

These terminals are used for emergency recording, auto time adjustment (Auto Adjust Time), taking measures against power
outages (Shutdown Time), and when installing a buzzer, a lamp, or similar alarm device. They are also used to synchronize
with the sequential display changeover.
The terminal pin array and connections are shown below. The
connector used should be compatible with the pin configuration.

Pin array

The pin array is different from other disk recorders. Make sure that
the connection is correct referring to the following.

Pin No.

q

Signal

Ch 8 alarm output

Operation

Alarm signal output at an event occurrence

Open collector output
24 V max., 100 mA

Starting emergency recording disk space a sig-
nal input

Generation of signal output for disk space alarm-
ing of DVD-RAM, DVD-R and CD-R

Open collector output
24 V max., 100 mA

Remarks

w

Ch 9 alarm output

e

Ch 10 alarm output

r

Ch 11 alarm output

t

Ch 12 alarm output

y

Ch 13 alarm output

u

Ch 14 alarm output

i

Ch 15 alarm output

o

Ch 16 alarm output

!0

NC

!1

Alarm reset input

!2

Emergency recording
input

!3, !4

Earth (Grounding)

!5

Alarm output for available
disk space of device con-
nected to copy port

Signal output upon detection of an HDD error

!6

HDD error output

Signal output upon detection of a camera error

!7

Camera error output

Signal output upon detection of a unit error

!8

Error output

Signal output upon completion of outage pro-
cessing

High (+12 V)

!9

End of outage process-
ing

The time of this unit is adjusted to the preset time
according to the signal input. This signal output is
then generated for the setting time of this unit.
Time of all other units is adjusted to the setting
time of this unit.

30 k

Ω 5 V pull-up,

–100 mA/make contact

@0

Time adjustment I/O

Sequence changeover is affected according to
the signal input. Signal output is generated at the
time of sequence changeover.

@1

Sequence changeover
I/O

The state of alarm suspension is assumed
according to the signal input.

@2

Alarm suspension input

Start of outage processing according to the sig-
nal input.

Non-voltage make contact input
–100 mA/5 V pull-up

@3

Outage detection I/O

Changeover to the external recording mode

@4

External recording mode
changeover

Canceling the alarm display

Non-voltage make contact input
–100 mA, 5 V pull-up

@5

+5 V output

+5 V output

200 mA max.

q

!3

@5

!4

ALARM/CONTOROL

Only for the WJ-HD316
(Not available for the WJ-HD309)

Advertising