Panasonic WJ-HD309 User Manual

Page 57

Advertising
background image

POWER

Warning

The power outage alert signal is sup-
plied from the uninterruptible power sup-
ply system (UPS). Internal processing
will start when the set time for "Shutdown
Time" on the "Basic Setup" menu of
"System" has passed after having
received the power outage alert signal.
(Refer to page 122.) When the internal
processing starts, recording will stop
and all operations will be invalid.

Press the ALARM RESET button to can-
cel the warning status. The unit will be in
the error half-reset/error reset condition.
The unit will start operation automatically
after the UPS starts power supply.

Press the ALARM RESET button to can-
cel the warning status. The unit will be in
the error half-reset/error reset condition.
If thermal errors occur frequently, the
unit may be malfunctioning. Contact the
dealer.

THERMAL

Warning

Thermal error of the unit or the optional
extension unit has been detected.

Press the ALARM RESET button to can-
cel the warning status. The unit will be in
the error half-reset condition. Consult the
dealer.

FAN

Warning

The fan of this unit or the optional exten-
sion unit is malfunctioning. It may pro-
duce an increase in temperature in the
unit and cause malfunction of the HDDs.

Indication

57

MEDIUM-n

REMOVE

Warning

Error

Press the ALARM RESET button to can-
cel the warning status. The unit will be in
the error half-reset/error reset condition.
Confirm that a disk has been inserted, or
check the inserted disk format.

Consult the dealer. After replacing the
hard disk, the "REMOVE" error status will
be canceled.

The external recording device is not
operable because no disk or different
format disk has been inserted, etc.

An error has occurred on the hard disk
and the hard disk has been unmounted
from the system automatically.

Status

Description

Solution

* : Camera number

# : Partition number (Refer to page 14.)

nn : Available disk space (percentage)

n : COPY port number to which an external recording device is connected

Note: The available disk space warning will be given only once when the available disk space has reached the set value. Mail

notification of an available disk space warning will be sent each time 1 % of the available disk space is reduced after the
available disk space has reached the set value. Refer to page 95 for descriptions of how to set the available disk space
(Disk Capacity) warning. For further information about mail notification of available disk space warning, refer to the Network
Setup Instructions (PDF).

Press the ALARM RESET button to can-
cel the error/warning status. The unit will
be in the error half-reset/error reset con-
dition. Initialize the DVD-RAM disk.
(Refer to page 52.) When initialized, all
recorded data will be deleted.

Press the ALARM RESET button to can-
cel the error/warning status. The unit will
be in the error half-reset/error reset con-
dition. Replace the disk with a new one.

The DVD-RAM disk is almost full or com-
pletely full.

The CD-R or DVD-R disk is almost full or
completely full.

#-nn% (available
disk space is run-
ning out)
#-FULL (no avail-
able disk space)

Error
Warning

The hard disk is almost full or completely
full.

Press the ALARM RESET button to can-
cel the error/warning status. The unit will
be in the error half-reset/error reset con-
dition. Initialize or replace the hard disk.
(Refer to page 128, 133.) When initial-
ized, all recorded data will be deleted. It
is recommended to copy the data using
an external recording device.

Advertising