Alarm connection – Panasonic WJ-HD309 User Manual

Page 88

Advertising
background image

88

Alarm connection

When a signal is supplied to the alarm input terminals of CH 1-16, recording and displaying of camera images will be per-
formed according to the settings.
When an alarm device such as a buzzer, a lamp, etc., is installed outside, connect them to the alarm output terminals (pin nos.
9 - 12, pin nos. 23 - 25) or to the alarm output terminals (pin nos. 1 - 9) of the ALARM/CONTROL terminal.

Alarming devices

Relay, etc.

Alarming devices

Install according to
your needs.

Relay, etc.

(GND)

Sensor

Security door
switch

(Ch 16 alar

m input)

(Ch 1 alar

m input)

o

!3

!3

o

!4

@2

q

(Ch 1 alarm output)

(Ch 16 alarm output)

(GND)

(GND)

Install according to
your needs.

ALARM

ALARM/CONTOROL

Time and polarities of the ALARM/CONTROL terminal and the ALARM terminal

Terminal

Alarm input

Alarm output

Alarm reset input

Emergency recording input

Alarm output for available disk space of
device connected to the copy port

HDD error output

Camera error output

Error output

Outage processing end output

Time adjust I/O

Sequence changeover output

Outage detection output

External recording mode changeover

Alarm suspend output

Active time

100 ms or more

The set time on the SETUP MENU

100 ms or more

100 ms or more

While the size of the available disk
space is less than the set size

Until the HDD error is cleared

Until the camera error is cleared

Until the error is cleared

100 ms

Input: 100 ms or more
Output: 1 s

100 ms or more

100 ms or more

100 ms or more

100 ms or more

Note

N.O.: L active
N.C.: H active

L active

L active

L active

L active

L active

L active

L active

H active

L active

L active

L active

L active, judged by level

L active, judged by level

Advertising