[ SYSTEM MENU ]

Quit

Transmit Mode

Maintenance Mode

[ MAINTENANCE MENU ]

Quit

PT Setting Status

I/O Check

Display History

Memory Init.

Memory Switches

Comm. Method
Key Press Sound
Buzzer Sound

RS-232C
OFF

Putting-Out Time
Resume Function

OFF
None
ON

[ MEMORY SWITCH MENU (1/2) ]

Support Tool Mode

NT600S

EXIT

SAVE

EXIT

NEXT
PAGE

         -   $0&  1   .  - 

Section 3-6

4-6-4

Setting the RS-232C Communication Conditions

When connecting the NT600S to the host by the RS-232C method, set the follow-
ing communication conditions.

Item

Setting

Factory-Setting

RS-232C Speed

2400/4800/9600/19200bps
(to be set to the same value as set for the Host)

2400bps

Data bit length

7 bits/8 bits

8 bits

Stop bit length

1 bit/2 bits

1 bit

Parity bit

Even/odd/none

None

Flow control

RS/CS control
XON/XOFF control
None

None

Select the required menu option from the System Menu by following the procedure
given below.

Select “Maintenance Mode”.

Select “Memory Switches”.

Press “NEXT PAGE”.
If the RS-232C has been se-
lected, the host link speed set-
ting does not make any effect.