Communications
port 1

Communications
port 2

I/O port
selector
switch

RS-232C

RS-422A

(RS-232C/

RS-422A)

(RS-232C)



    $   & ' (

Section 2-4

Connecting to a PC with a 9-pin Connector

Use a connector cable with a 9-pin connector on both ends to connect the NT600S
to a PC with a 9-pin connector.

Host I/F connector
(RS-232C 9-pin type)

SYSMAC C series
PC, CVM1/CV
series PC

Host link unit/CPU unit

9-pin connector

RS-232C connector cable

9-pin connector

NT600S

The connector cable wiring for the C series CPU unit (C



H) is different from that

for the other PCs. For details, refer to Appendix E Method for Making the Cable for
Connection to the PC/Host (page 264).

Connecting the NT600S to a CVM1/CV Series Host Link Unit

Two types of connectors are provided to CV500-LK201 host link unit. Both of these
connector types can connect to the NT600S with an RS-232C connector cable.
Select the connector cable which matches the connector type.



To connect to communication port 1

This is a 25-pin RS-232C connector. Use a connector cable with a 25-pin con-
nector on one end and a 9-pin connector on the other end (NT600S side).



To connect to communication port 2

This is a 9-pin RS-232C/RS-422A connector. Use a connector cable with a 9-pin
connector on both ends.

Set the I/O port selector switch to the RS-232C side (upper side) to use this port.

Connecting the NT600S to a C Series CQM1 Unit

CQM1 can connect to the NT600S by the RS-232C method. Use an RS-232C
9-pin type connector cable.



To connect to the RS-232C port

This is a 9-pin RS-232C connector. Use a connector cable with a 9-pin connector
on both ends.

Connecting to C Series C200HX/HG/HE

When using C series C200HX/HG/HE models, the NT600S can be connected to
the standard port of the CPU unit, or to ports A and B of the expansion communica-
tion board. Procure an RS-232C type connection cable for the connection. For
details on the specifications, installation method, etc., of the communication board
used for the connection, refer to the “SYSMAC C200HX/HG/HE Installation
Guide” (W302-E1-



).