Section 4-6

When a lamp is overlapped with a memory table display

The guide display message for a lamp is a fixed character-string. If you want to
change the lamp guide display in accordance with some condition, overlap the dis-
play area of a numeral memory table or character-string memory table with the
lamp. However, note that -- as shown below -- different results will be achieved
depending on the timing of the lighting of the lamp and the updating of the memory
table. Bear this in mind when creating the control program.

Example 1 :Lamp lit after the memory table is updated

Lamp OFF

Character-string memory
table display area

Memory table
updated

Lamp turned
ON

Lamp OFF

Lamp ON

The characters are
displayed white on black.

Lamp

OMRON

PT

PT

Example 2 :Memory table updated while lamp is lit

Lamp OFF

Character-string memory
table display area

Lamp turned
ON

Memory table
updated

Lamp ON

Lamp ON

The characters are
displayed white on black.

Lamp

OMRON

OMRON

The memory table display
area of the lit lamp is
overwritten.

PT