Omron NT-series Programmable Terminal V022-E3-1 User Manual

Page 78

Advertising
background image

Note

Caution



&    !"#"

Section 2-8

Connec-

i

Signal name

Abbrevi-

i

Signal direction

tor pin #

g

ation

Input

Output

1

Frame ground

FG

---

---

2

Send data

SD (TXD)

---

Yes

3

Receive data

RD (RXD)

Yes

---

4

Request to send

RS (RTS)

---

Yes

5

Clear to send

CS (CTS)

Yes

---

6

+5V 150mA Max. (ST211(B)-EV



)

100mA Max. (ST121(B)-EV



)

+5 V

---

Yes

9

Signal ground

SG (GND)

---

---

1. FG is not connected internally in the NT600S.

2. Unlisted pins are not used.

For cable parts and the wiring method, refer to APPENDIX E Method for Making
the Cable for Connection to the PC/Host (page 264).

Connecting to the Host Computer

Use a cable that is compatible with the RS-232C connector of the host to connect
the NT600S and the host.
In the example shown here, the cable connects the 9-pin connector of the NT600S
and 25-pin connector of the host. If the host has a 9-pin RS-232C connector, use
an RS-232C cable with 9-pin connectors at both ends.

NT600S

25-pin
connector

Host Interface connector
(RS-232C, 9-pin type)

9-pin
connector

RS-232C cable



Turn off the NT600S power supply when connecting or disconnecting connec-
tors.



After connecting a communication cable, always secure it with the screws.



Check that the current capacity of the equipment to be supplied is within 150 mA
before using the +5V output of pin No.6. Otherwise, the product may malfunc-
tion.

The current capacity of +5 V output of NT600S is:

+5 V



5%, 150 mA max. with ST211(B)-EV



, and

+5 V



5%, 100 mA max. with ST121(B)-EV



.

Advertising