Caution



              $

Section 5-5

6-5

Notification of the Operating Status to the PC
(Determining the NT600S Operating Status)

The status (operating statuses, etc.) of the NT600S can be determined from the
PC by reading the “PT status” word in the PT status notify area allocated in the PC
memory.

NT600S

PC

PT stopped

PT status notify area

Currently displayed screen

Screen
number

Content upgrade memory table

PT status

6-5-1

Ascertainable NT600S Statuses (Notified Operating Statuses)

[“PT status notification bits” of the PT status notify area]

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit

0

0

0

0

Word
m+2

PT status notification bits

0

0

PT status

Battery
(1 (ON) = low / 0 (OFF) = normal)

Screen switch strobe flag

Numeral setting strobe flag

PT operating status
(1(ON) = operating / 0 (OFF) = stopped)

15 14 13 12 11 10

9

8

Bit

The NT600S statuses that the PC can determine are listed below.

Low voltage of battery installed in NT600S (battery: option)

NT600S operating/stopped status

Screen switches

Data input



PT operating status (bit 15)

When the NT600S is in the RUN mode this bit is set to ON (1). In other modes
and while the system menu is displayed it is OFF (0). When this bit is OFF allo-
cated bits and words cannot be read or written to.

During the run mode, ON (1) is periodically written into this bit. In order to check
whether the NT600S is operating normally or not, write OFF (0) to this bit : if it is
ON (1) 30 seconds later the NT600S is running, and if it is OFF (0), the NT600S
is stopped.

In order to ensure system safety, be sure to periodically read the PT operating
status bit at the host during operation to confirm that the PT is always operating
correctly.