881/882 Video Test Generator User Guide (Rev A.22)

127

5. Disconnect the source generator from the Ethernet cable and connect the target

generator.

Note: If both generators on the Ethernet/IP network you do not have to disconnect the
generator.

6. Access the target generator’s FTP Browser.

7. Delete the current system and library resource folders from the target generator’s flash

memory as follows:

a. In the

Instrument Files area, click the down arrow by the Look in box and select

tffs0 (FlashMem).

b. Select all of the files in the lower pane.

c. Click the

Delete button. A confirmation dialog box appears.

d. Click

OK to delete the files.

8. Copy the source system and library folders from the PC to the target generator’s flash

memory as follows:

a. In the

Host Files area, open the folder containing the system and library folder.

b. Select the system and library folders in the lower pane.

c. In the

Instrument Files area, click the down arrow by the Look in box and select

tffs0 (FlashMem).

d. In the

Host Files area, click Download. A confirmation dialog box appears. Click

OK to download the source files to the generator.

9. Reboot the generator by cycling the power.