9. (Optional) Click the

Save button on the toolbar to save the trace to a file. The Save

Trace dialog box appears. Navigate to the folder where you want to save the file. In the
File Name box, type a name for the file, and then click Save.

Passive monitoring between a source and a sink

The procedures for following procedures provide instructions on how to passively monitor
the auxiliary channel between a DisplayPort sink device and a DisplayPort source device.

To passively monitor the DisplayPort transactions between a source and a sink:

1. Configure the generator to operate in the DisplayPort mode.

To set up the generator

for DisplayPort:

” on page 505.

2. Connect an DisplayPort-to-DisplayPort cable between the DisplayPort connector on

the source device under test and the DisplayPort connector on the 882E labeled

To

Source.