Chapter 2 Testing Video Displays

Testing analog computer (IT) CRTs

This section describes how to test analog computer (IT) displays. The display responses
shown as examples in the procedures use the 882C. However you can also test analog
composite with the 882D using the same format and image selections. The interface
selection is different and is noted.

To set up the generator to test an analog computer CRT:

1. Connect a standard VGA cable between the VGA connector on the generator and the

VGA connector on the display under test.

2. Calibrate the generator in accordance with the procedures described in

Calibrating

signal level

” on page 87.

3. Determine the formats to test (see

Setting Source list of formats

” on page 43).

4. Determine additional formats to test based on the resolution of the display. The VESA

formats are shown below:

5. Determine the images to test. For analog CRTs, you typically want to select images to

test for geometry, focusing, photometry, resolution, cross talk, EMI, and regulation
characteristics. For more details on what images test these specific display attributes,
see

Selecting image

” on page 47 or Appendix B, “

Image Reference

.”

To activate the VGA interface on the output port:

1. Press the

Interface key to access the list of interfaces. A listing of signal interfaces

appears on the generator’s display as shown below.

Standard

Quantum Data format name

VGA

DMT06xx

SVGA

DMT08xx

XGA

DMT10xx

SXGA

DMT12xx

UXGA

DMT16xx

QXGA

DMT20xx

QSXBA

DMT25xx

VGA
HDMI-D

CVBS

S-VIDEO

SDI

*

HDMI-H