Troubleshooting – Cobalt Digital FUSION 3G 9901-UDX 3G_HD_SD Up Down_Cross Converter User Manual

Page 124

Advertising
background image

3

Troubleshooting

3-70

9901-UDX PRODUCT MANUAL

9901-UDX-OM (V1.15)

Analog audio not processed or
passed through card.

Analog input/output DIP
switches not set to match
intended use for analog rear
module port.

Each analog channel corresponding to rear
module analog audio ports has input/output port
direction selectors that set the AES as input or
output.

Make certain port is set as input or output, as
intended, in accordance with Setting I/O
Switches for Analog Audio (1-8) Ports (p. 2-1)
.

(+ENCD, +ENCE options only)
Encoder will not accept external
RS-485 metadata.

RS-485 A and B signals
reversed (“flipped”).

Conventions using RS-485 are not always
consistent across devices. If the A and B
differential feeds are reversed, the encoder will
not recognize the signal.

This card uses the following convention per
EIA-485:

A is inverting () pin
B is non-inverting (+) pin
G is ground/common

Reversing the A and B connections in this error
case typically solves this problem.

Card will not retain user settings,
or setting changes or presets
spontaneously invoke.

GPI Controls tab GPI

Coding set to Binary with no
controlled GPI source
connected to GPI inputs

• If GPI is not to be used, make certain GPI

Coding control on GPI Controls tab is set to
Disabled. (If control is left on Binary with no
inputs, the pull-up HI logic state on the open
inputs will be interpreted as two “HI’s” on the
inputs, resulting in an invoked preset).

Event Based Loading

sub-tab inadvertently set to
trigger on event

• If event based loading is not to be used,

make certain Event Based Presets is
disabled (either using master Enable/Disable
control or through events settings. See Event
Based Preset Loading (p. 3-56) for
more
information.

Card spontaneously disconnects
from remote control; card
displays red error card-edge LED

• Card software error

• In the extremely unlikely case this error

occurs, the card will display

1. Go to the Log tab and follow the on-screen

instructions to download the generated log
file to connected computer. After the file
downloads, the card reboots and the error
indication will be cleared.

2. Send the log file to Cobalt product support.

Cobalt Engineering will analyze the log and
typically respond with corrective action.

Table 3-4

Troubleshooting Processing Errors by Symptom — continued

Symptom

Error/Condition

Corrective Action

Advertising