5.2.9 Request / Response Attributes

The table contains an overview of the possible attributes of the PROFIdrive parameter channel.

Field

Data type

Values

Remark

Request reference

Unsigned8

0x01..0xFF

Request ID

Unsigned8

0x01

request parameter value

Identification for read or write request

0x02

change parameter value

0x42

change parameter non-volatile

0x51

request par. value double word

0x52

change par. value double word

Response ID

Unsigned8

0x01

request parameter (+) Positive

Identification for the response

0x02

change parameter (+) Positive

0x81

request parameter (-) Negative

0x82

change parameter (-) Negative

Axis

Unsigned8

0x00..0xFF

number (always 0)

Number of parameters Unsigned8

0x01..0x25

Limitation: DP V1 message length

Attribute

Unsigned8

0x10

value

0x20

description

Data description

0x30

text

Number of elements

Unsigned8

Limitation: DP V1 message length

0x01-0xFA

Quantity 1-234

Parameter number

Unsigned16

0x0001...

number 1-65535

Parameter number

0xFFFF

Subindex

Unsigned16

0x0000

number 0-65535

Array pointer

0xFFFF

Format

Unsigned8

See table

Number of values

Unsigned8

0x01..0xEA

Quantity 0-234

Limitation: DP V1 message length

Error number

Unsigned16

0x0000...

Error number

5.2.10 Request Reference

Unique identification of request/response pair for the master. The master changes the request reference with each new request. The slave mirrors the request
reference in the response.

5.2.11 Request ID

The following request identifications are defined:

0x01

Request parameter

0x02

Change parameter (Data are NOT stored in non-volatile memory, lost at power cycle)

0x42

Change parameter non-volatile (Data are stored in non-volatile memory)

0x51

Request parameter value double word. (All parameters are formatted and transferred as Double Word size, regardless of the actual data
type)

0x52

Change parameter value double word. (All parameters must be formatted and sent as Double Word size, regardless of data type)

5.2.12 Response ID

The Response ID indicates if the Read or Write request was successfully performed in the frequency converter. If the response is negative, the request is answered
negative (first bit = 1) and an error code is entered per partial response, instead of the value.

5.2.13 Axis

The axis attribute should be set to zero.

AF-650 GP/AF-600 FP Profibus DP Operating Instructions