6.3 PROFIBUS-specific Parameter List

Parameter

Default value

Range

Conver-
sion index

Data type

par. O-01 Control Site

Dig. & ctrl. word [0]

[0 - 2]

-

Uint8

par. O-02 Control Word Source

Drive RS485 [0]

[0 - 4]

-

Uint8

par. O-03 Control Word Timeout Time

1

0.1-18000

-1

Uint32

par. O-04 Control Word Timeout Function

Off [0]

[0 - 10]

-

Uint8

par. O-05 End-of-Timeout Function

Hold set-up [0]

[0 - 1]

-

Uint8

par. O-06 Reset Control Word Timeout

Do not reset [0]

[0 - 1]

-

Uint8

par. O-07 Diagnosis Trigger

Disable [0]

[0 - 3]

-

Uint8

par. O-10 Control Word Profile

GE Drive profile [0]

[0 - x]

-

Uint8

par. O-50 Coasting Select

*Logic OR [3]

[0 - 3]

-

Uint8

par. O-51 Quick Stop Select

*Logic OR [3]

[0 - 3]

-

Uint8

par. O-52 DC Brake Select

*Logic OR [3]

[0 - 3]

-

Uint8

par. O-53 Start Select

*Logic OR [3]

[0 - 3]

-

Uint8

par. O-54 Reversing Select

*Logic OR [3]

[0 - 3]

-

Uint8

par. O-55 Set-up Select

*Logic OR [3]

[0 - 3]

-

Uint8

par. O-56 Preset Reference Select

*Logic OR [3]

[0 - 3]

-

Uint8

par. O-90 Bus Jog 1 Speed

100 rpm

0 - par. F-17

67

Uint16

par. O-91 Bus Jog 2 Speed

200 rpm

0 - par. F-17

67

Uint16

par. PB-15 PCD Write Configuration

-

-

-

Uint16

par. PB-16 PCD Read Configuration

-

-

-

Uint16

par. PB-18 Node Address

126

1 - 126

0

Uint8

par. PB-22 Telegram Selection

-

[0 - 108]

-

Uint8

par. PB-23 Parameters for Signals

-

0 - 573

-

Uint16

par. PB-27 Parameter Edit

Enabled [1]

[0 - 1]

-

Uint16

par. PB-28 Process Control

Enable cyclic master [1]

[0 - 1]

-

Uint16

par. PB-44 Fault Message Counter

0

[0 - 8]

0

Uint16

par. PB-45 Fault Code

0

-

-

Uint16

par. PB-47 Fault Number

0

-

-

Uint16

par. PB-52 Fault Situation Counter

0

0 - 1000

0

Uint16

par. PB-53 Profibus Warning Word

0

16 bits

0

V2

par. PB-63 Actual Baud Rate

No baud rate found [255]

9.6-12000 kbits

0

Uint8

par. PB-64 Device Identification

0

[0 - 10]

0

Uint16

par. PB-65 Profile Number

0

8 bits

0

Uint8

par. PB-70 Edit Set-up

Active set-up [9]

[0 - 9]

-

Uint8

par. PB-71 Profibus Save Data Values

Off [0]

[0 - 2]

-

Uint8

par. PB-72 ProfibusDriveReset

No action [0]

[0 - 2]

-

Uint8

par. PB-80 Defined Parameters (1)

-

0-115

0

Uint16

par. PB-81 Defined Parameters (2)

0-115

0

Uint16

par. PB-82 Defined Parameters (3)

-

0-115

0

Uint16

par. PB-83 Defined Parameters (4)

-

0-115

0

Uint16

par. PB-90 Changed Parameters (1)

-

0-115

0

Uint16

par. PB-91 Changed Parameters (2)

-

0-115

0

Uint16

par. PB-92 Changed Parameters (3)

-

0-115

0

Uint16

par. PB-93 Changed parameters (4)

-

0-115

0

Uint16

par. DR-84 Comm. Option STW

0

0 - FFFF

0

V2

par. DR-90 Alarm Word

0

0 - FFFF

0

Uint32

par. DR-92 Warning Word

0

0 - FFFF

0

Uint32

Please refer to the relevant Operating Instructions for a comprehensive parameter list.