1.7 Assumptions
This manual assumes you are using the AF-6 Series Drives Profibus DP Communications Module in conjunction with an AF-650 GP or AF-600 FP drive. It is also
assumed that your master is a PLC or PC equipped with a serial communication card supporting all the PROFIBUS communication services required by your
application, and that all requirements stipulated in the PROFIBUS standard, as well as those set up in the PROFIBUS Variable Speed Drive Profile and its company-
specific implementation PROFIdrive, as well as those pertaining to the AF-6 Series Drive are strictly observed as well as all limitations therein fully respected.
1.8 Hardware
These Operating Instructions relate to the Profibus network Model No. OPCPDP.
The Profibus Option will be identified as: OPCPDP Profibus DP V1 in par. ID-60 Option Mounted.
1.9 Background Knowledge
The Profibus DP Communications Module is designed to communicate with any master complying with the PROFIBUS standard. Familiarity with the PC or PLC
you intend to use as a master in your system is assumed. Issues regarding hardware or software produced by other manufacturers are beyond the scope of this
manual, and are not the responsibility of GE.
If you have questions regarding set-up of master-to-master communication, or communication to a non-GE slave, please consult the appropriate manuals.
1.10 Available Literature
For additional AF-6 Series Drives information please visit www.geelectrical.com/drives.
1.11 Abbreviations
ACI
Acyclical Control Interval
AOC
Application Orientated Controller
CAN
Controller Area Network
CTW
Control Word
DP
Distributed Periphery
DU
Data Unit
EEPROM
Electrical Erasable Programmable Read Only Memory
EIA
Electronic Industries Alliance: Specifier of the EIA Standard RS 485-A
EMC
Electromagnetic Compatibility
FDT
Field Device Tool
IND
Sub index
ISO
International Standards Organization
LCD
Liquid Crystal Display
LED
Light Emitting Diode
MAV
Main Actual Value
MC1
Master Class 1
MC2
Master Class 2
MOC
Motion Orientated Controller
MRV
Main Reference Value
NDL
Network Data Link Layer
PB
PROFIBUS
PC
Personal Computer
PCD
Process Data
PCA
Parameter Characteristics
PCV
Parameter-Characteristics-Value
PDU
Protocol Data Unit
PLC
Programmable Logic Control
PNU
Parameter Number
PPO
Parameter-Process Data
PVA
Parameter Value
RC
Request/Response Characteristics
SAP
Service Access Point
SMP
Spontaneous Message
STW
Status Word
AF-650 GP/AF-600 FP Profibus DP Operating Instructions
8
1