EV Charging Station

User Manual & Installation Instructions

GE EV Charging Station User Manual

14 of 86









Locate area for pedestal location








Locate area for double pedestal location.







Install conduits for power wire and communication wire (if required). Allow approximately 5” length for
each conduit above the concrete level as shown in Figure 13. Cut as necessary to final dimensions.
Route power conduit and communication conduit through the center of the hole in the mounting
template, appropriately.

Install base mounting assembly plate securely over conduits with mounting template and four 1/2-13
nuts.

WARNING: Make sure power to the EVSE is

disconnected before performing any task

CONDUIT

MOUNTING TEMPLATE

BASE MOUNTING
ASSEMBLY

CONCRETE

Figure 11

Figure 12