EV Charging Station

User Manual & Installation Instructions

GE EV Charging Station User Manual

24 of 86

In case of RFID sensor, the communication cable is connected to the Ethernet connector on the
controller, just like the pedestal as shown in Figure 9.































Field wiring entry from bottom:
If this option is preferred, remove the two knockouts at the bottom of the enclosure and fill in the
unused cable holes on the back of the enclosure using the spare NEMA 3R knockout plugs provided.
See Figure 24. Assemble the supplied conduit hub in the bottom and make the conduit arrangement.









Ground Bar

Fuse Block



Incoming Power Cables
Connect at Terminals of
Fuse Block

Ground Wire Connects to
Ground Bar



Figure 23: Power Wire and Ground Wire Connections for Wall Mount