g

EV Charging Station

User Manual & Installation Instructions

GE EV Charging Station User Manual

55 of 86





(This picture depicts an example of all CLOSED dip switch positions. For correct settings, refer to below
tables)

The default settings per SKU are given in below table:

1

2

3

4

5

6

7

8

Factory
setting

Factory
setting

Factory
setting

Factory
setting

reserved Language settings Config.

server

CLOSED CLOSED CLOSED OPEN

CLOSED OPEN *) OPEN *) CLOSE **)


*) Language Settings

6 position

7 position

No Display or Set Language Via Config. Server

Close

Close

Spanish

Close

Open

French

Open

Close

English

Open

Open


**) Configuration Server

CLOSE = Normal operation
OPEN = Configuration server

3.5.2 Display fault messages


EVSE controller is capable of providing a full range of Fault troubleshooting options. When the
controller experiences a fault it will display the brief fault description message as well as the specific
fault code on the display.

Fault codes:

0x00000001
Fault indicating that the unit has experienced a ground fault and is waiting the required amount of
time (15 minutes) before it attempts to reclose the main contactor, clear the fault and continue
charging.

0x00000002
Fault indicating that the controller has experienced the maximum allowed number of ground faults
for a charge cycle.. To reset this fault simply disconnect the EVSE plug from the vehicle, and wait for at
least 30 seconds.

Pushed down on “number”

side is the CLOSED position

Figure 55: Dip Switch Settings