GE Industrial Solutions NEMA EVSE CHARGING STATION User Manual

Page 49

Advertising
background image

g

EV Charging Station

User Manual & Installation Instructions

GE EV Charging Station User Manual

49 of 86




After the access card is swiped, the RFID LED returns to red until authorization is successful.

Once authorized, the RFID LED will return to green until the transaction is ended when the vehicle is
disconnected.

If authorization is denied, the RFID LED remains red and the VFD will display the “denied” message.

Connecting to a Vehicle: Before connecting the EVSE to a vehicle, make sure the status indicator at
the top of the EVSE is SOLID GREEN. The VFD should prompt the user to remove plug from socket and
connect to vehicle. If the EVSE is displaying RED, then do not use the EVSE and contact GE technical
support for assistance.

If the EVSE status indicator is SOLID GREEN, then
1.When the EVSE handle is seated in the EVSE holder, press and hold the button on the EVSE handle
and pull away from the EVSE holder until it is fully removed. The VFD should prompt the user to
connect cable to vehicle.
2.Press and hold the button on the EVSE handle and insert into the vehicle’s inlet socket. Release the
button on the EVSE handle when fully connected to the vehicle inlet socket.

Once the EVSE handle is connected to the vehicle, the status indicator will turn BLINKING GREEN or
AMBER. BLINKING GREEN indicates that the vehicle is connected, but not ready to charge.

Figure 53: EVSE during card swipe

Advertising